Valve level indicator - U 10-716 PN 16


Application
It is used as water direct-reading instrument
for various bins, reservoirs, tanks for fluids,
which are non-aggressive for brass. This level
indicator is for service pressures up to PN 16
and temperatures up to 200°C. The indicator
must not be used for toxic, aggressive or
crystallic substances.

Technical description
Level indicator has upper and inferior head,
level indicator glass tube with 20 mm outside
diameter. Upper heads have flap gates,
inferior head have drain plug. Max. centre to
centre is H=1500 mm.

Connecting and face-to-face dimensions
Connecting and face-to-face dimensions are
given in the table below.

Installation
Level indicator is installed vertically with
drain plug in low position.


Go to
WWW Intersigma Indusrial a.s.