Yoke gate valve - S 35 111-610 PN 10



Operation
The gate valve can be operated by handwheel (ON 13 31111),
chainwheel (ON 13 3131), electric servomotor or from a stand
(ON 13 3140 and ON 13 3142).

Application
Shut-off valve for water, steam and other non-
aggressive liquids and gases, for service
pressures and temperatures:


The gate valve is not suitable for flow regulation

Technical description
The yoke gate valve has a rising non-rotating
stem with its thread outside the valve
chamber. The stem nut is turned to raise or
lower the stem and solid wedge. Body and
wedge sealing surfaces are pressed brass or
stainless steel sealing rings. Stem is sealed
with gland packing in a yoke.

Connecting and face-to-face dimension
Face-to-face dimension as per ÈSN EN 558
(DIN 3202/F4, F5).
Flange connection dimensions as per
ÈSN 13 1060, DIN 2501.
Flange faces as per ÈSN 13 1061, DIN 2526.

Material
Body, bonnet, wedge grey cast iron (GG 25)
Stem stainless steel (13 Cr)
Body sealing surfaces brass, 13Cr
Wedge sealing surfaces brass, 13Cr
Gland packing asbestos-free fibre

Testing
The gate valve is tested per ÈSN 13 3060,
part 2 DIN 3230-3.

Installation
The gate valve can be installed in horizontal
or vertical piping.

Go to